Friday, March 23, 2018

The simple design for the installation of ventilation system

AMX electric fan suppliers.The ventilation system is based on two systems, one is to deliver the fresh air from outdoor to indoor, the other is reject the polluted air from indoor to outdoor, this forms an air flow field within the sealed house, in order to refresh the air continuously.

The solution would be:

Use the high pressure air flow but with lower power consumption brushless motor to drive the centrifugal fan, this centrifugal fan will blow the fresh air from outdoor to indoor, the other centrifugal fan will also blow the polluted air from indoor to outdoor. During this process, the system will filter, antivirus, oxygenation and preheat the air, moreover, it will also recovery the heat.


The design principle for the working plan.

The working plan should include descriptions, arrangement diagram for ceiling, arrangement diagram for floor and the ventilator installation working plan.

Descriptions.

Based on the size of the house to design the working plan.


Ceiling arrangement diagram for return air.

Based on the needs of the house to design the ventilation system.

Ceiling arrangement diagram for supply air.

Based on the needs of the house to design the ventilation system.


Arrangement diagram for floor supply air.

Based on the needs of the house to design the ventilation system.


The installation for the ventilator.

Main installations.
The attentions for ventilator installation.
A.Build the main structure for ventilator based on its size, and make the rust prevention.
B.Please install the ventilator on the roof in level condition, please located it as close as to the pipeline.
C.When install the ventilator with the structure, use the rubber for damping, please remember to remain the whole structure in level condition.
Please leave enough space when install the ventilator, for future maintenance. For indoor ceiling installation, remember to leave a 450*450 access hole near it, for future replacement and maintenance.
Deploy the power system according to the power consumption and voltage. It should be designed with independent power supply, correct connection, strength and with ground connection. It should has the independent control system.
Use the UPVC material pipeline, using flexible connection with the products, and better be within 35cm.

For air outlets, the flexible connection can’t be longer than 5m, use UPVC material pipeline for connection longer than 5m.

The attentions for the pipeline installation.

The directions, diameter of the pipe and the installation location must be all according to the design.

The section of the pipe must be smooth. The connections must be sealed, tight and clean.

The pipeline must be installed in level condition, no sundries within the pipeline.

Use support when install the pipeline, if use the hoop instead, then cling its in-plane to the ektexine. The support should be firm fixation.

All the pipeline which is going through the wall, must use mechanical holing, please don’t change the position of the pipeline.

The distance between hanger and holder.

The length of flexible metal pipe or non-metallic pipe can’t be longer than 5 m, better in perfect conditions.
The attentions for the installation of the wind gap.
Use foaming agent to seal the air inlets, and have the water-prof process.
When install the air outlets, choose the position which is close to the ventilator to open the whole, the size should be 130mm. After drilling the whole, use foaming agent to seal the space. Use the PEF tape to seal the rain-prof air outlets with the wall. The air outlets should be installed correctly, smoothly and beautifully.
The air inlets in the kitchen should be away from the hearth.
The air inlets should be located close to clean and neat space.
The pipe material should use PVC with composite hose together.